                     Shokri R,  Tabaraei B,  Hatami S,  Nilchizade Rahbar O. Rapid identification of Salmonella in dairy products by P-CEIA.  Iran J Med Microbiol 2012; 5 (4) :29-34
URL: 
http://ijmm.ir/article-1-205-en.html   
                    
                    
                    
					 
					
                 
                
                    
                    
                    
                    1- Biopharmaceutical production quality supervisor at Pasteur Institute of Iran. , shokrei@gmail.com
 2- Biopharmaceutical production quality supervisor at Pasteur Institute of Iran. 
                    
                    
                    Abstract:       (11311 Views)
                    
                    
                    Background  and  Objectives:  The aim  of  this  study  is  to use  P-CEIA (Polymixin-Coated 
Polyester  Cloth  in  EIA)  method  for  rapid  isolation  of  salmonella  in  dairy  products. 
While  other  methods  such  as  bacterial  culturing  and  ELISA  (ab-EIA)  are  time 
consuming and expensive, P-CEIA has been utilized for this study.
Materials  and  Methods:  Different dilutions of S.typhimorium Ra-30 in Buffered peptone 
water (BPW, pH=7.4) and also ten samples (milk and butterfat) have been studied by 
two P-CEIA and ab-EIA methods. 
Results:  Analyzing  of  findings  indicates  that  by  using  the  standard  strains  of 
S.typhimorium  Ra-30,  sensitivity  for  P-CEIA  method  was  106  cfu/mL  while  ab-EIA 
was estimated 105 cfu/mL. This sensitivity was balanced after heat treatment by using 
the sodium deoxy -cholate as a detergent five and three positive results were allocated to 
unknown milk and butterfat samples which were tested with Ab-EIA and also six and 
three positive results were allocated to unknown milk and butterfat samples which were 
tested with P-CEIA. In addition to the  P-CEIA method requires 14 hour process time 
less than ab -EIA method. 
Conclusion:  Analyzing  of  findings  indicates  that  P-CEIA  method  is  more  privileged 
cause  of  its  firm-inexpensive  and  stable  process  for  Salmonella  detection  in  dairy 
products.
                    
                    
                    
                    
                    
                    Type of Study:  
Original Research Article |
                    Subject: 
                    
Medical Bacteriology  Received: 2014/01/3 | Accepted: 2014/01/3 | ePublished: 2014/01/3