<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Journal of Medical Microbiology</title>
<title_fa>مجله میکروب شناسی پزشکی ایران</title_fa>
<short_title>Iran J Med Microbiol</short_title>
<subject>Medical Sciences</subject>
<web_url>http://ijmm.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-8612</journal_id_issn>
<journal_id_issn_online>2345-4342</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.30699/ijmm</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1402</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2023</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<volume>17</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی اصلاح حسگر ایمنی با اکسید گرافن کاهش‌یافته با نانوذرات طلا بر روی الکترود کربن شیشه‌ای در بدون برچسب برای تشخیص &lt;i&gt;اشریشیا کلی&lt;/i&gt;</title_fa>
	<title>Investigation of Immunosensor Modification With Reduced Graphene Oxide with Au Nanoparticles on Glassy Carbon Electrode in Label-free for &lt;i&gt;Escherichia coli&lt;/i&gt; Detection</title>
	<subject_fa>نانو بیوتکنولوژی در پزشکی</subject_fa>
	<subject>Nanotechnology In Medicine</subject>
	<content_type_fa>مقاله پژوهشی</content_type_fa>
	<content_type>Original Research Article</content_type>
	<abstract_fa>&lt;p style=&quot;font-style: normal; text-align: justify;&quot;&gt;&lt;span class=&quot;sanspYW&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:IRANsans;&quot;&gt;&lt;span style=&quot;color:#ffffff;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;background-color:#16a085;&quot;&gt;زمینه و اهداف:&amp;nbsp;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:IRANsans;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;اشریشیا کلی یک شاخص باکتریایی ضروری در کنترل کیفیت دارویی و سایر زمینه های مشابه است. (&lt;em&gt;E.coli&lt;/em&gt;) برخی از حسگرهای زیستی برای تشخیص آن بر اساس روش&#8204;های انتقال الکتروشیمیایی طراحی شده&#8204;اند. یک حسگر زیستی با اکسید گرافن کاهش یافته اصلاح شد. روش&#8204;های سنتی زمان&#8204;بر و قیمت بالایی هستند، بنابراین در این مطالعه از حسگر زیستی جدید با اصلاح اکسید گرافن احیا شده (rGO) به عنوان نوعی ترکیب کربن روی الکترود کربن شیشه&#8204;ای (GCE) با تزئینات نانوذرات طلایی (Au NPs) برای E استفاده شد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span class=&quot;sanspYW&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:IRANsans;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color:#ffffff;&quot;&gt;&lt;span style=&quot;background-color:#16a085;&quot;&gt;مواد و روش کار:&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&amp;nbsp;&lt;/strong&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:IRANsans;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;rGo اصلاح&#8204;شده بر روی GCE و روش&#8204;های زمان&#8204;آمپرومتریک و کاهش برای تزئین NPs طلا استفاده شد و با آنتی&#8204;بادی پلی کلونال &lt;em&gt;E. coli&lt;/em&gt; و محلول ۰.۵ W/V٪ آلبومین سرم گاوی (BSA) تکمیل شد. مورفولوژی و ساختار NPs rGO و Au در GCE/rGO/Au NPs/ آنتی بادی پلی کلونال &lt;em&gt;E. coli&lt;/em&gt;/ بیوسنسور BSA توسط SEM (میکروسکوپ الکترونی روبشی) در طی مراحل اصلاح تأیید شد. تشخیص &lt;em&gt;E. coli&lt;/em&gt; در نمونه&#8204;های غیرمشابه با روش&#8204;های ولتامتری موج مربعی (SWV) و ولتامتری چرخه&#8204;ای (CV) انجام شد که در محلول بافر فسفات ۰.۱ مولار (PBS) (pH ۷.۴) مخلوط با ۰.۵ میلی&#8204;مولار استامینوفن قرار گرفتند. در مقایسه با بیوسنسور، روش کلاسیک تشخیص با رقت&#8204;های سریال &lt;em&gt;E. coli &lt;/em&gt;ATCC ۸۷۳۹ (۱&amp;times;۱۰۱&amp;ndash;۱&amp;times;۱۰۸ CFU/ml) انجام شد که روی محیط کشت کشت داده شد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span class=&quot;sanspYW&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:IRANsans;&quot;&gt;&lt;span style=&quot;color:#ffffff;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;background-color:#16a085;&quot;&gt;یافته ها:&amp;nbsp;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:IRANsans;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;علی&#8204;رغم دو روش مورد استفاده برای تثبیت نانوذرات طلا، تصاویر میکروسکوپ الکترونی روبشی (SEM) نشان داد که اختلاف فعلی به دلیل ذرات طلا افزایش نمی&#8204;یابد. اصلاح آن تغییر قابل توجهی در جریان نداشت و آزمایش موفقی برای تشخیص اشریشیا کولی نبود.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span class=&quot;sanspYW&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:IRANsans;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color:#ffffff;&quot;&gt;&lt;span style=&quot;background-color:#16a085;&quot;&gt;نتیجه&#8204;گیری:&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&amp;nbsp;&lt;/strong&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:IRANsans;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;در مقایسه با روش پلیت، بیوسنسور نمی&#8204;تواند جایگزین روش&#8204;های مرسوم برای تشخیص&lt;em&gt; E. coli&lt;/em&gt; شود.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family:Times New Roman;&quot;&gt;&lt;span style=&quot;font-size:16px;&quot;&gt;&lt;span style=&quot;color:#ffffff;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;background-color:#16a085;&quot;&gt;Background and Aim:&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&amp;nbsp;&lt;i&gt;Escherichia coli&lt;/i&gt; &lt;i&gt;&amp;nbsp;&lt;/i&gt;(&lt;i&gt;E.coli&lt;/i&gt;) is an essential bacterial indicator in the control of pharmaceutical quality and other similar fields. There are some biosensors designed for its detection based on electrochemical transduction methods.&lt;b&gt; &lt;/b&gt;A biosensor with reduced graphene oxide was modified. Traditional methods are time-consuming and high prices, so in this study a new biosensor with modification of reduced graphene oxide (rGO) as a kind of carbon composition on glassy carbon electrode (GCE) with Au Nanoparticles (Au NPs) decoration was used for &lt;i&gt;E. coli&lt;/i&gt; detection.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-family:Times New Roman;&quot;&gt;&lt;span style=&quot;font-size:16px;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color:#ffffff;&quot;&gt;&lt;span style=&quot;background-color:#16a085;&quot;&gt;Materials and Methods:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&amp;nbsp;&lt;span style=&quot;color:black&quot;&gt;Reduced graphene oxide (rGO) &amp;nbsp;modified on glassy carbon electrode (GCE) &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:16px;&quot;&gt;&lt;span style=&quot;font-family:Times New Roman;&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt; and chronoamperometric and reduction methods were used for Au NPs decoration and it was completed with polyclonal &lt;/span&gt;&lt;i&gt;&lt;span style=&quot;line-height:200%&quot;&gt;E. coli&lt;/span&gt;&lt;/i&gt;&lt;span style=&quot;line-height:200%&quot;&gt; antibody and 0.5 W/V% Bovine Serum Albumin (BSA) solution.&lt;/span&gt; &lt;span style=&quot;line-height:200%&quot;&gt;Morphology and structure of rGO and Au NPs in GCE/rGO/Au NPs/ &lt;/span&gt;&lt;em&gt;&lt;span style=&quot;line-height:200%&quot;&gt;E. coli&lt;/span&gt;&lt;/em&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&amp;nbsp;polyclonal antibody/ BSA biosensor were verified by SEM (Scanning Electron Microscope) during modification steps. &lt;i&gt;E. coli&lt;/i&gt; detection in dissimilar samples was performed by Square-Wave Voltammetry (SWV) and Cyclic Voltammetry (CV) techniques which were set in 0.1M phosphate buffer solution (PBS) (pH 7.4) mixed with 0.5mM acetaminophen. In comparison with the biosensor, the classical method of detection was performed with serial dilutions of &lt;i&gt;E. coli&lt;/i&gt; ATCC 8739 (1&amp;times;10&lt;sup&gt;1&lt;/sup&gt;&amp;ndash;1&amp;times;10&lt;sup&gt;8&lt;/sup&gt; CFU/ml) which was cultured on media.&lt;/span&gt;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-family:Times New Roman;&quot;&gt;&lt;span style=&quot;font-size:16px;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color:#ffffff;&quot;&gt;&lt;span style=&quot;background-color:#16a085;&quot;&gt;Results:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:16px;&quot;&gt;&lt;span style=&quot;font-family:Times New Roman;&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;Despite the two methods used to stabilize Au NPs, scanning electron microscope (SEM) images showed that the current difference did not increase due to gold particles. Its modification had not significant change in current and it was not a successful experiment for &lt;i&gt;E.coli&lt;/i&gt; detection.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-family:Times New Roman;&quot;&gt;&lt;span style=&quot;font-size:16px;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color:#ffffff;&quot;&gt;&lt;span style=&quot;background-color:#16a085;&quot;&gt;Conclusion:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:16px;&quot;&gt;&lt;span style=&quot;font-family:Times New Roman;&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;Compared with the plate method, biosensor couldn&amp;rsquo;t substitute with conventional methods for &lt;i&gt;E. coli&lt;/i&gt; detection.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;/p&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;div&gt;&lt;/div&gt;&lt;/p&gt;</abstract>
	<keyword_fa>اکسید گرافن احیا شده, حسگر زیستی, E. coli, نانوذرات طلا</keyword_fa>
	<keyword>Reduced graphene oxide, Biosensor, E. coli, Au NPs</keyword>
	<start_page>464</start_page>
	<end_page>473</end_page>
	<web_url>http://ijmm.ir/browse.php?a_code=A-10-186-6&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Fatemeh</first_name>
	<middle_name></middle_name>
	<last_name>Behoftadeh</last_name>
	<suffix></suffix>
	<first_name_fa>فاطمه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>به افتاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>fbehoftadeh@yahoo.com</email>
	<code>100319475328460026130</code>
	<orcid>100319475328460026130</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Microbiology, Faculty of Basic Sciences, Lahijan Branch, Islamic Azad University, Lahijan, Iran</affiliation>
	<affiliation_fa>گروه میکروب شناسی، دانشکده علوم پایه، واحد لاهیجان، دانشگاه آزاد اسلامی، لاهیجان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Ali</first_name>
	<middle_name></middle_name>
	<last_name>Mojtahedi</last_name>
	<suffix></suffix>
	<first_name_fa>علی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مجتهدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mojtahedi99.a@gmail.com</email>
	<code>100319475328460026131</code>
	<orcid>100319475328460026131</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Microbiology, School of Medicine, Iran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه میکروب شناسی، دانشکده پزشکی، دانشگاه علوم پزشکی ایران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad</first_name>
	<middle_name></middle_name>
	<last_name>Faezi Ghasemi</last_name>
	<suffix></suffix>
	<first_name_fa>محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فائزی قاسمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>faezi_m@yahoo.com</email>
	<code>100319475328460026132</code>
	<orcid>100319475328460026132</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Microbiology, Faculty of Basic Sciences, Lahijan Branch, Islamic Azad University, Lahijan, Iran</affiliation>
	<affiliation_fa>گروه میکروب شناسی، دانشکده علوم پایه، واحد لاهیجان، دانشگاه آزاد اسلامی، لاهیجان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Khosro</first_name>
	<middle_name></middle_name>
	<last_name>Issazadeh</last_name>
	<suffix></suffix>
	<first_name_fa>خسرو</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عیسی زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Issa_kaam@yahoo.com</email>
	<code>100319475328460026133</code>
	<orcid>100319475328460026133</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Microbiology, Faculty of Basic Sciences, Lahijan Branch, Islamic Azad University, Lahijan, Iran</affiliation>
	<affiliation_fa>گروه میکروب شناسی، دانشکده علوم پایه، واحد لاهیجان، دانشگاه آزاد اسلامی، لاهیجان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mostafa</first_name>
	<middle_name></middle_name>
	<last_name>Golshekan</last_name>
	<suffix></suffix>
	<first_name_fa>مصطفی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>گل شکن</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mostafa.golshekan@gmail.com</email>
	<code>100319475328460026134</code>
	<orcid>100319475328460026134</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Guilan Road Trauma Research Center, Guilan University of Medical Sciences, Rasht, Iran</affiliation>
	<affiliation_fa>مرکز تحقیقات ترومای جاده گیلان، دانشگاه علوم پزشکی گیلان، رشت، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
